476
Interface Specifics
Section 7-4
Timing Chart
Basic Operation:
Servo Unlock:
Function
• The axis is moved while the bit [JOG Operation] stays ON.
• [Axis Override] is applied to the speed. For details of timing, etc., see
“Relation between Task Override and Axis Override” (page 462).
1
0
Tu
1
0
1
0
Tu
Turning OFF the bit [Servo Lock]
will not cause Servo Unlock.
Turning OFF the bit [Servo Unlock]
will not cause Servo Lock.
Axis Control Bit:
Servo Lock
Axis Control Bit:
Servo Unlock
Axis Status Bit:
In Servo Lock
1
0
1
0
1
0
Tu
Tu
Cannot execute Servo Lock because
the bit [Servo Unlock] is ON.
Cannot execute Servo Lock because the
bit [Servo Unlock] has been turned ON
before the bit [In Servo Lock] is turned ON.
Turning OFF the bit [Servo Lock] before the
rise of the bit [In Servo Lock] will not interrupt
the processing (i.e. the bit [In Servo Lock] will
be turned ON).
Axis Control Bit:
Servo Lock
Axis Control Bit:
Servo Unlock
Axis Status Bit:
In Servo Lock
Word
Variable
Bit
Name
I/O
x+0
-
x+31
IW0440
-
IW045F
04
JOG Operation (Axis 1)
-
JOG Operation (Axis 32)
Output
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...