![Omron CS1W-MCH71 - Скачать руководство пользователя страница 486](http://html1.mh-extra.com/html/omron/cs1w-mch71/cs1w-mch71_operation-manual_742367486.webp)
441
Interface Specifics
Section 7-4
• The bit [Unit Ready] will be turned ON after the power is turned ON, the
initial processing is completed, and the motion task becomes ready to
receive commands.
• During normal operations, the bit [Unit Ready] will be turned OFF when
an alarm that requires the system stop occurs.
Effect on Other Functions
• When the bit [Unit Ready] is OFF, all the commands from the cyclic area
will be ignored.
• Whether the motion program can be actually executed or not depends on
the bit [Command Disabled/Enabled] of the axis declared by PROG com-
mand.
System Parameters
Nil
Program Example
The MC Unit supports processing of great amounts of data and varieties of
peripheral devices to realize multi-axis applications. Due to the fact, it takes
the MC Unit a certain period of time (8 seconds min.) to get ready for opera-
tion.
Additionally, the MC Unit and CPU Unit establish communications asynchro-
nously. To make the MC Unit receive instructions from PLC without fail, make
sure to send instructions from the CPU Unit to the MC Unit when the bit [Unit
Ready] is ON.
<Example of always using Task 1 and 2 as start tasks>
Note
Programs (for arithmetic operation, etc.) that do not use axes may start
motion tasks with the bit [Unit Ready], however, programs that use axes
require interlock for the used axes as shown above.
Timing Chart
Nil
Function
The bit [External Forced Stop Request] indicates the occurrence of a forced
stop request from something other than the input variable. The bit [External
Forced Stop Status] indicates the status of the stop caused by a forced stop
request.
n+15.00
x+32 to 63.03
n+15.00
+0 to 31.15
x+32 to 63.13
Unit Ready
Unit Ready
In Automatic
Mode
In Servo Lock
Command
Disabled/
Enabled
n+4.01
Motion Task 1 Start
n+5.01
Motion Task 2 Start
Interlock
Word
Variable
Bit
Name
I/O
n+15
OW0303
07
External Forced Stop Request
Input
08
External Forced Stop Status
Input
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...