![Omron CS1W-MCH71 - Скачать руководство пользователя страница 123](http://html1.mh-extra.com/html/omron/cs1w-mch71/cs1w-mch71_operation-manual_742367123.webp)
78
System Parameters
Section 4-2
Note
For details of Accel/decel patterns, see
(Page
248).
Explanation
Sets the S-curve filter time constant at the interpolation feed rate.
Explanation
Sets the combination of the interpolation Accel/decel time and Pass mode
with fixed acceleration enabled/disabled.
0: Interpolation acceleration time + Pass mode with fixed acceleration
disabled
1: Interpolation deceleration time + Pass mode with fixed acceleration
disabled
2: Interpolation acceleration time + Pass mode with fixed acceleration
enabled
3: Interpolation deceleration time + Pass mode with fixed acceleration
enabled
Note
(1) 2 and 3 are enabled when specifying only 1 axis with MOVEL command.
(2) Interpolation override in Pass mode with fixed acceleration is disabled
during deceleration caused by insufficient remaining travel distance.
(3) Pass mode with fixed acceleration cannot complete the passing opera-
tion under the following condition. After a deceleration stop, the next op-
eration is executed.
Distance required for deceleration stop from current speed > Travel dis-
tance of the next block
(4) The bank switching method for acceleration and deceleration times can
be selected for unit version 3.1 and later by switching P0004 (unit function
selection) bit 13 (interpolation acceleration/deceleration bank switching
option).
0: Selects the same banks for acceleration and deceleration times.
1: Selects different banks for acceleration and deceleration times.
MOVEL, MOVEC, and MOVETRAV can be specified separately. Enabled
for both pass mode and stop mode.
(5) There are several acceleration/deceleration times that can be used in the
pass operation. For details, see
(Page
248).
No.
Address in MC
Unit
Name
Type
Unit
Immediate
updating
P00M05
5024h +
(M * 20h)
Interpolation S-curve time con-
stant
Data
ms
Yes
Data configuration
Setting range
00000000 to 00007530 Hex
(0 to 30000)
Initial value
00000064 (100)
31
00
S-curve time constant
No.
Address in MC
Unit
Name
Type
Unit
Immediate
updating
P00M06
5025h +
(M * 20h)
Pass mode select
Data
---
No
Data configuration
Setting range
00000000 to 00000003 Hex
(0 to 3)
Initial value
00000000 (0)
31
00
Pass mode select
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...