xxvi
Function Improvements
for Unit Version 2.0
Jogging
Communications Levels
Communications Cycle and Unit Cycle
LATCH Command Processing Time
Previous versions
Current version (Unit Ver. 2.0)
The JOG feed direction is set or reversed
as follows:
• Use the JOG/STEP Direction Bit to
specify the feed direction.
• Turn ON the JOG Bit.
• To reverse the feed direction, turn OFF
the JOG Bit.
• After the axis is stopped, reverse the
JOG/STEP Direction Bit.
• Turn ON the JOG Bit. The feed direction
will be reversed.
As shown below, a setting for reverse
operation has been added.
• Use the JOG/STEP Direction Bit to spec-
ify the feed direction.
• Turn ON the JOG Bit.
• The feed direction is reversed by revers-
ing the JOG/STEP Direction Bit even
while the JOG Bit still ON.
Use the following parameter to switch the
previous function and the new one.
• Parameter number: P00004
• Bit: 05 (previously reserved)
0: Initial value. Same as previous func-
tion.
1: Selects new function.
Previous versions
Current version (Unit Ver. 2.0 or later)
The MC Unit supported communications
on up to three levels.
The MC Unit supports communications on
up to eight levels, according to the eight
levels supported by the CPU Unit. The
CPU Unit supports eight levels with unit
version 2.0 or later.
Previous versions
Current version (Unit Ver. 2.0 or later)
The MC Unit communications cycle and
unit cycle times are as follows:
Communications cycle: 1 ms, 2 ms, 4 ms
Unit cycle: 1 ms, 2 ms, 4 ms, 8 ms
• Supporting a communications cycle of
3 ms enable more precise performance.
Communications cycle: 1 ms, 2 ms,
3 ms, 4 ms
Unit cycle: 1 ms, 2 ms, 3 ms, 4 ms, 6 ms,
8 ms
• Use the following parameter to switch the
previous function and the new one.
Parameter number: P00004
Bit: 03 (previously reserved)
0: Initial value. Same as previous func-
tion.
1: Enables use of 3 ms.
Previous versions
Current version (Unit Ver. 2.0 or later)
The time from when the LATCH com-
mand is executed until the external latch
signal is detected is as follows:
• When latch signals are received at any
position: 105 to 232 ms
• When only latch signals in a specified
position range are received: 105 to
232 ms
As shown below, performance is improved
in cases where latch signals are received
at any position.
• When latch signals are received at any
position: 3 to 24 ms
• When only latch signals in a specified
position range are received: 105 to
232 ms
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...