400
Allocations for the CPU Unit
Section 7-3
Unit status bit
n+15
OW0303 00
Unit Ready
0: Unit is not ready for accepting commands
1: Unit is ready for accepting commands
01
Unit Alarm
0: No alarm occurring on Unit level or Unit Alarm
Reset is ON
1: Alarm occurring on Unit level
02
Flash Save Com-
pleted
0: Neither parameter nor position data save is com-
pleted
1: Parameter or position data save completed
(including error completion)
03
Teaching Warning
0: Teaching condition setting, execution completed
successfully
1: Condition error, Command disabled, No origin,
Address overflow
04
Teaching Condition
Setting Completed
0: When Teaching condition setting bit is OFF
1: Teaching condition setting completed (including
error completion)
05
Teaching Execution
Completed
0: Teaching execution is OFF
1: Teaching execution completed (including error
completion)
06
Reserved
Reserved
07
External Forced Stop
Request
0: There is no forced stop request from anything
other than input variables
1: There is forced stop request from something
other than input variables
08
External Forced Stop
Status
0: No forced stop request, or processing for stop
1: Stop by external forced stop request completed
09
Operating Mode
(Supported in Unit
Ver. 3.0 or later)
Displays the current MC Unit operating mode.
0: RUN or CPU Mode
1: Tool Mode
10-11
Reserved
Reserved
12-15
Present Value Moni-
tor Status
Indicates the present value monitoring output sta-
tus
0: Zero output
1: Feedback position (coordinate system currently
being selected)
2: Feedback position (machine coordinate system)
3: Command position (coordinate system currently
being selected)
4: Command position (machine coordinate system)
5: Feedback speed 1 (command unit/min)
6: Feedback speed 2 (depends on the parameter)
7: Command speed 1 (command unit/min)
8: Command speed 2 (depends on the parameter)
9: Error
10: Torque command
11-15: Reserved for system
Reserved
n+16
OW0320 00
Reserved
Reserved
01
Reserved
Reserved
02-15
Reserved
Reserved
Classification
Word
Variable
bit
Name
Specifications
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...