![Omron CS1W-MCH71 - Скачать руководство пользователя страница 316](http://html1.mh-extra.com/html/omron/cs1w-mch71/cs1w-mch71_operation-manual_742367316.webp)
271
Basic Information
Section 6-1
A command of the next block can be executed during S-curve deceleration.
However, if the command is to be executed after completion of the previous
command's output (as it should be for CAM, etc.), STOPMODE or PASS-
MODE command can be used to control the execution.
When MOVEL
→
MOVE command was executed in Pass Mode:
Program example:
PROG P0001 Q00000001;
PASSMODE;
INC MOVEL [J01] 10000 F100000; Interpolation feed S-curve filter enable
INC MOVE [J01] 10000; Rapid feed S-curve filter disable
END;
When MOVEL
→
MOVE command was executed in Stop Mode:
Program example:
PROG P0001 Q00000001;
STOPMODE;
INC MOVEL [J01] 10000 F100000;
INC MOVE [J01] 10000;
END;
6-1-6
Synchronous Command
There are five different types of synchronous commands.
• MOVELINK: Link operation start
• CAMBOX:
Electronic cam, synchronous
• CONNECT: Electronic shaft
• SYNC:
Trailing synchronization
• ADDAX:
Travel distance superimpose
Master Axis
• Any MC Unit axis can be used as a master axis. Axis declaration by
PROG command (program start) is not required for the axes to be used
only as master axes.
0
Trapezoidal Waveform
S-curve Waveform
Speed
Time
0
Speed
Trapezoidal Waveform
S-curve Waveform
Time
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...