611
Slave Modules
Section 10-2
Output variables
Address
Bit
Symbol
Name
Description
OW0050
0
M-SET1
Counter 1
Mode set
The counter mode setting signal
ON: Mode setting signal is effective
1
N-SET1
Counter 1
Notch point setting
The notch point setting preset signal
Notch point is set at the rise of the signal (OFF-ON).
2
P-SET1
Counter 1
Current value setting
The counter’s current value preset signal
Current value is set at the rise of the signal (OFF-ON).
3
C-ENB1
Counter 1
Count enable
Input pulses can be counted when this is ON.
ON: Count enabled
4
N-ENB1
Counter 1
Notch output enable
Notch output can be output when this is ON.
ON: Notch output enabled
5
P-RES1
Counter 1
Current value reset
Counter’s current value is reset to “0”.
Current value is reset at the rise of the signal (OFF-ON).
6
N-RES1
Counter 1
Notch output reset
Latch status for notch output is reset.
Latch status is reset at the rise of the signal (OFF-ON).
7
L-RES1
Counter 1
Count value reset
Input status of external latch is reset.
Input status is reset at the rise of the signal (OFF-ON).
8
M-SET2
Counter 2
Mode set
The counter mode setting signal
ON: Mode setting signal is effective
9
N-SET2
Counter 2
Notch point setting
The notch point setting preset signal
Notch point is set at the rise of the signal (OFF-ON).
10
P-SET2
Counter 2
Current value setting
The counter’s current value preset signal
Current value is set at the rise of the signal (OFF-ON).
11
C-ENB2
Counter 2
Count enable
Input pulses can be counted when this is ON.
ON: Count enabled
12
N-ENB2
Counter 2
Notch output enable
Notch output can be output when this is ON.
ON: Notch output enabled
13
P-RES2
Counter 2
Current value reset
Counter’s current value is reset to “0”.
Current value is reset at the rise of the signal (OFF-ON).
14
N-RES2
Counter 2
Notch output reset
Latch status for notch output is reset.
Latch status is reset at the rise of the signal (OFF-ON).
15
L-RES2
Counter 2
Count value reset
Input status of external latch is reset.
Input status is reset at the rise of the signal (OFF-ON).
OW0051
0
N-ON1
Counter 1
Forced notch output
Notch output is forced ON.
ON: Forced output
1
N-ON2
Counter 2
Forced notch output
Notch output is forced ON.
ON: Forced output
2 to 7
Not used
8
MON1
Monitor 1
Combining the ON/OFF status of Monitor 1 to 3 enables
monitoring of the followings.
• Counter current value
• External latch data
• Status
• Mode settings
• Counter 1, Notch point setting value
• Counter 2, Notch point setting value
• Current set value
9
MON2
Monitor 2
10
MON3
Monitor 3
11 to 15
Not used
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...