![Omron CS1W-MCH71 - Скачать руководство пользователя страница 310](http://html1.mh-extra.com/html/omron/cs1w-mch71/cs1w-mch71_operation-manual_742367310.webp)
265
Basic Information
Section 6-1
If the speed of axes exceeds the speed specified in the parameter [P2AA01:
Maximum rapid feed rate], the speed will be limited as shown in the table
below:
Override
Multiplying the override and the interpolation feed rate can change speed of
the operation in progress. The task override is used for the interpolation feed
rate. Range of the task override is between 0 and 327.67%. When a value
outside of the range is set, the override 0% is used. If the distributed interpola-
tion feed rates on the axes exceed the speeds specified in the parameter
[P2AA01: Maximum rapid feed rate] for the axes, the maximum speed of the
axis that has the longest travel distance (the fastest axis) will be used as the
upper limit.
For details on the task override, see
7-4-3 Motion Task Control Bits
Command
Speed limit operation
MOVEL
Interpolation feed rate is limited in order to prevent the speed of the
axis that has the longest travel distance from exceeding the speed
specified in the parameter [P2AA01: Maximum rapid feed rate].
MOVEC
Speed of axes is not checked.
MOVETRAV
Interpolation feed rate is limited in order to prevent the speed of
rotation axis from exceeding the speed specified in the parameter
[P2AA01: Maximum rapid feed rate].
100%
40%
70%
100%
40%
70%
100%
100%
40%
70%
40%
Ignored during
deceleration
Move start
command
Task override
Axis movement
output
MOVEL command
70%
.
.
.
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...