206
Servo Parameter
Section 4-8
4-8-4
Setting Method Using Combination of W Series and NS115
This section explains the servo driver's parameter setting method with combi-
nation of W-series servo driver and NS115.
The following user constants are expressed as restricted constant, deter-
mined constant, expansion constant, and disabled constant.
Determined constant: To be reset to the settings in the following table if the
value is outside of the setting value when the power is turned ON.
Approximately three seconds will be added during the re-setting.
Expansion constant: This is the parameter to expand a function when install-
ing the NS115.
Disabled constant: Neither alarm nor warning occurs even when changed.
900D
Position loop
gain address
• This is the address of the position loop
gain.
Note
Selecting the motor model automati-
cally sets this parameter.
Note
Entering numerical value cannot
change this parameter.
Data
0000 (0)
---
No
900E
Position loop
gain index
• Sets the unit system for the position loop
gain.
• Set 0000 Hex when the W Series and
NS115 are combined, and set 0001h for
W-series Servo Drivers with built-in com-
munications.
Data
0000 (0)
---
No
No.
Name
Configuration and explanation
Type
Initial
value
Unit
Immediate
updating
15
00
Position loop gain address
15
00
Position loop gain index
User constant
No.
Name
Content
Setting
Remark
Pn004.1
Electronic gear conversion of the
feedback count in position control
No conversion
0
Determined constant
Pn004.2
Control mode switch
Execute
1
Determined constant
Pn004.3
Access cycle S-shape filter
Disable
0
Determined constant
Pn200.2
Clear operation
Clears only with CLR com-
mand.
1
Determined constant
Pn207.1
Position control option
Speed feed forward on V-REF 1
Determined constant
Pn50A.0
Input allocation
Input signal custom setting
1
Determined constant
Pn50A.1
/SVON
Disable
8
Determined constant
Pn50B.1
/ALMRST
Disable
8
Determined constant
Pn50C
/SPD-D, -A, -B, /C-SEL
Disable
8888
Determined constant
Pn50D
/ZCLAMP, /INH, /G-SEL, /P-DET
Disable
8888
Determined constant
Pn002.3
Full-closed encoder usage
Expansion constant
Pn005
Advanced function select switch 5
Expansion constant
Pn206
No. of Full-closed encoder pulses
Expansion constant
Pn511
Input signal select 5
Expansion constant
Pn200.0
Command pulse mode
0
Disabled constant
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...