VOL.2-1311
MG-T1(SIP) [SCA-24DTIA]
F
Setting Default Gateway IP address:
F
Setting IP address, port number, and host name of SIP server:
Input new Host Name:
mgt1.nec.com
Enter new host name of MG-T1(SIP) in full-
domain format.
e.g. mgt1.nec.com
(*Up to 63 bytes of alphanumeric characters,
. (period), and - (hyphen) is available.)
--- Default Gateway IP Address set ---
Current Default Gateway: 0.0.0.0
The current setting is displayed.
Change Default Gateway? [Y (change)/N (current)/
Q(quit)]:
y
Asked whether to change the displayed set-
ting.
Y: Change the setting
N: Remain the current setting
Q: Exit this setting
Input new Default Gateway:
10.41.1.254
Enter the IP address of the default gateway.
e.g. 10.41.1.254
(*Note that default gateway should be located
in the same segment with MG-T1(SIP).)
--- SIP Server IP Address & Host Name set ---
Current SIP Server/IP Address/Port Number/Host Name:
SIP Server
IP Address
Port Number
Host Name
1
2
:
:
19
20
0.0.0.0
0.0.0.0
:
:
0.0.0.0
0.0.0.0
5060
5060
:
:
5060
5060
The current setting of the Telephony Server
information (IP address, port number, and host
name) is displayed.
Change SIP Server Information? [Y (change)/N (cur-
rent)/Q(quit)]:
y
Asked whether to change the displayed setting.
Y: Change the setting
N: Remain the current setting
Q: Exit this setting
Input new SIP Server (1-20):
1
Enter the number of SIP server [1-20].
Input new IP Address:
10.41.1.200
Enter the IP address of SIP server.
e.g. 10.41.1.200
Input new Port Number:
5060
Enter the port number of SIP server.
Default: 5060
Is there the Host Name? [Y/N]:
y
Asked whether to use host name.
Y: Use host name
N: Do not use host name
Input new Host Name:
SVR1.nec.com
Enter the host name of SIP server in full-domain
format.
e.g. SVR1.nec.com
(*Up to 63 bytes of alphanumeric characters, .
(period), and - (hyphen) is available.)
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...