VOL.3-540
CHAPTER 4
CONFIGURATION SETUP
PC Port Settings Menu
STEP 4:When “1.Speed & Duplex” is selected by pressing “1” key:
Specify the LAN speed and communication method (full-duplex or half-duplex).
Autonegotiation is set by pressing “1” key.
100Mbps speed and full-duplex mode are set by pressing “2” key.
100Mbps speed and half-duplex mode are set by pressing “3” key.
10Mbps speed and full-duplex mode are set by pressing “4” key.
10Mbps speed and half-duplex mode are set by pressing “5” key.
The default is “Autonego”.
When “2.Port VLAN Mode” is selected by pressing “2” key:
Select whether to enable or disable the port VLAN (PC port). Press “1” key to disable Port
VLAN. Press “2” key to enable Port VLAN. The default VLAN Mode is “1. Disable”.
When “3.Port VLAN ID” is selected by pressing “3” key:
Enter port VLAN ID (0-4094). The default port VLAN ID is 7.
When “4.Port VLAN Priority” is selected by pressing “4” key:
Specify the port VLAN Priority (0-7). The default port VLAN Priority is 5.
When “5.Port Available” is selected by pressing “5” key:
Press “1” key to set PC Port to “Automatic” (default setting). PC Port is disabled/enabled
according to directions from the System.
Press “2” key to disable the PC port.
Note:
For DtermIP (SIP) with Firmware Version earlier than 3.0.0.0:
Select whether to enable or disable the PC port. Press "1" key to disable the PC port. Press "2" key to en-
able the PC port. PC port is enabled by the default setting.
When “6.EAPOL Forwarding” is selected by pressing “6” key:
Select whether to enable or disable the EAPOL Frame Forwarding function. Press “1” key to
disable the EAPOL Frame Forwarding function. Press “2” key to enable the EAPOL Frame
Forwarding function.
Note:
For DtermIP (SIP) with Firmware Version earlier than 4.1.x.x:
EAPOL Frame Forwarding function port is enabled by the default setting.
For DtermIP (SIP) with Firmware Version 4.1.x.x or later:
EAPOL Frame Forwarding function port is disabled by the default setting.
Up
Down
Exit
1621.Speed & Duplex
2.Port VLAN Mode
3.Port VLAN ID
4.Port VLAN Priority
5.Port Available
6.EAPOL Forwarding
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...