VOL.2-265
MC & MG with PFT
4.
Setting ToS of DRS session:
You can set ToS of DRS in the following two ways.
Note:
The result of data setting is shown in a 1-byte (hexadecimal) format in accordance with the setting dialog
followed by the prompt. The meaning of 1-byte data is shown below:
Note:
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
mand.
5.
Setting Health Check Receive Timer
Line 1: Enter sub command name PRECEDENCE to set
the following parameters - Delay, Throughput,
Reliability, and Cost - respectively. Specify the
value to each parameter.
Line 2: Precedence: 0-7 (low-high) (default=6)
Line 3: Delay: 0/1=Normal (default)/Low Delay ON
Line 4: Throughput:
0/1=Normal (default)/High Throughput ON
Line 5: Reliability:
0/1=Normal (default)/High Reliability ON
Line 6: Cost: 0/1=Normal (default)/Cost Precedence
ON
Line 7: Result is shown
MC-MG> SET DRSTOS PRECEDENCE
PRECEDENCE (0-7) : 6
DELAY (0/1) : 0
THROUGHPUT (0/1) : 0
RELIABILITY (0/1) : 0
COST (0/1) : 0
DRS TOS setting succeeded.(0xC0)
Prec.=PRECEDENCE (3 bits)
D=Delay
T=Throughput
R=Reliability
C=Cost
0=not used
Prec.
D T R C 0
Line 1: Enter the sub command name VALUE to set the
DRS setting value directly.
Line 2: Specify the value in the range of 00-FF (de-
fault=C0)
Line 3: Result is shown
MC-MG> SET DRSTOS VALUE
TOS (00-FF) : C0
DRS TOS setting succeeded. (0xC0)
MC-MG> SET INTERFACE
SPEED (AUTO/100M/10M): 10M
DUPLEX (FULL/HALF): HALF
MC-MG> SET HC_TIMER 150
Health-Check Timer Timeout setting succeeded.
Line 1: Enter the time (second) in the range of 120-240
(at intervals of 30 seconds) (default=150)
Line 2: Result is shown
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...