VOL.2-958
MG-PRI/PRA
Conditions Check
After the settings, make sure that MG-PRI/PRA is working properly, taking the following:
STEP 1
Make sure that PWR lamp lights on.
If the lamp does not light on, check the following:
•
Check if the cable is inserted appropriately.
•
Check if the power switch is inserted appropriately.
•
Check if the electricity is provided on the plug.
•
Check if the FAN alarm is detected.
STEP 2
Make sure that LINK lamp lights on.
If the lamp does not light on, check the following:
•
Check the cable between network equipment and MG-PRI/PRA
•
Check the power of connected equipment (such as Router and Switching HUB)
•
Check an appropriate cable type is used.
STEP 3
Make sure that ON LINE lamp lights on.
If the lamp does not light on, check the following:
•
Check the settings of MG-PRI/PRA with
SHOW
command from Maintenance Console, and check the
MGC related data specified in the Telephony Server with appropriate commands (ASYD, ASYDL,
ADPM, ADTM, ARTD, ARTI, ATRK, ADPC, ACSC, ACIC1, AMGIL, AMGVL) from PCPro. For
more information about its MGC commands, refer to CHAPTER4. When confirming the Telephony
Server settings, refer to the Command Manual and the Data Programming Manual.
STEP 4
Make sure that LINE D lamp lights on.
If the lamp on MG-PRI/PRA does not light on, check the following:
•
Check the system message output.
For more details, refer to the Operations and Maintenance Manual.
•
Check MG-PRI/PRA is connected to ISDN physically
- Check the cable between MDF and MG-PRI/PRA
- Check the cable between MDF and DSU
•
Check the connection of the cable between MDF and DSU
•
Check the settings of MG-PRI/PRA by
SHOW
command from Maintenance Console, and check the
MGC related data specified in the Telephony Server by using appropriate commands (ASYD, ASYDL,
ADPM, ADTM, ARTD, ARTI, ATRK, ADPC, ACSC, ACIC1, AMGIL, AMGVL) from PCPro. For
more information about its MGC commands, refer to CHAPTER4. When confirming the Telephony
Server settings, refer to the Command Manual and the Data Programming Manual.
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...