VOL.2-989
MG-PRI/PRA
28.
SET
Δ
TCS_T1_3
Δ
[
P1
]
This command is used to specify T1 data. To make this assignment effective, it is required to execute the
"SAVE" command and to restart before exiting the maintenance command.
P1
-Specify a set value
0000-FFFF
= Set value (default value: 00CC)
When
P1
is omitted
→
COMMAND 1
When
P1
and
P2
are specified
→
COMMAND 2
<COMMAND 1>
1) Specify 4K Data Link
0
=MOS (default)
1
=BOS
2) Specify G.704 Mode
0
=ITU-T G.704 (default)
1
=JG.704
3) Specify BOS/MOS Operation
When 0 is specified for 4K Data Link:
0
=Sending MOS Message periodically/
Receiving MOS Message
1
=Sending Mark /Receiving MOS Message
2
=Sending MOS Flag /Receiving MOS Message
3
=Sending MOS Flag /Not Receiving MOS Message
When 1 is specified for 4K Data Link
-When 0 is specified for G.704 Mode:
0
=Sending 7E, 7E /Receiving BOS Message
1
=Sending FF, FF /Receiving BOS Message
2
=Sending FF, 7E /Receiving BOS Message
3
=Sending FF, FF /Not Receiving BOS Message
-When 1 is specified for G.704 Mode:
0
=Sending 7E, 7E /Receiving BOS Message
1
=Sending 00, 00 /Receiving BOS Message
2
=Sending 00, 00 /Receiving BOS Message
3
=Sending 00, 00 /Not Receiving BOS Message
4) Specify Signaling A Logic-Recovery
1
(fixed)
5) Specify Signaling Pattern Recovery
2
(fixed)
6) Enable/Disable Signaling A Logic Sending
1
(fixed)
7) Specify Signaling Pattern Sending
2
(fixed)
<COMMAND 2>
A command is executed, and the result is displayed.
MG-PRI > SET TCS_T1_3
4K Data Link ( 0/1:0 ): 0
G.704 Mode ( 0/1:0 ): 0
BOS/MOS Operation ( 0-3:0 ): 0
Signaling A Logic-Recv( 0/1:1 ): 1
Signaling Pattern-Recv( 0-3:2 ): 2
Signaling A Logic-Send( 0/1:1 ): 1
Signaling Pattern-Send( 0-3:2 ): 2
set value is 0x00CC
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
COMMAND 1
MG-PRI > SET TCS_T1_3 00CC
set value is 0x00CC
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
COMMAND 2
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...