VOL.2-237
MC & MG with PFT
<When registering to SP-PHI>
MG part of MC&MG can be registered to either Internal PHI-BRI or SP-PHI. Here explains MC&MG data as-
signment for registering to SP-PHI. When registering to Internal PHI-BRI, refer to
.
[1] Internal PHE Data Assignment
When MG part of MC&MG is registered to SP-PHI, MPH is used to control SP-PHI. For the use of MPH, it is
required to make Internal PHE function valid. So Internal PHE data assignment is necessary. About the proce-
dure for the Internal PHE data assignment, refer to Vol.1, Chapter 2, “2. IP Related Basic Programming” in this
manual. The explanation of PHs including Internal PHE is also there.
[2] SP-PHI Data Assignment
When MG part of MC&MG is registered to SP-PHI, SP-PHI data assignment is necessary. About the procedure
for the SP-PHI data assignment, refer to Vol.1, Chapter 2, “2. IP Related Basic Programming” in this manual.
The explanation of PHs including SP-PHI is also there.
[3] MG Data Assignment
Assign the necessary System Data for using the MG (COT).
ASYD: Assignment of System Data
SYS1
INDEX 186, b6=1 (ISDN/MG (COT) is in service)
INDEX 187=00 (Fixed)
INDEX 474 Guard Timer For Originating Call (MTC
×
TC)
bit 0-3 (MTC)
bit 4-6 (TC)
Note:
When assigning 1H, TC = 64 msec.
ARTD: Assignment of Route Class Data
Assign the Route Class Data for Virtual Speech Channel. The following data setting is necessary besides
Analog C.O BWT setting.
CDN1 OSGS = 0
CCIS
CDN60 TC/EC = 1
Echo Canceler is available
CDN114 DCH = 1
Unify the channel
CDN125 MGCOT = 1
MG (COT) is available
When digits conversion is required for the received digits, assign the following data.
CDN66 (DC): Dialed Number Confirmation
Note:
Assign the number of digits for identifying the incoming line. Count the digits from the last one of the re-
ceived number.
<Related to MF>
CDN 72 MFSP
Sending Speed (0-15)
CDN 73 KPPT
Duration of KP sending (0-15)
CDN 74 KPST
Pause after KP sending (0-15)
CDN 75 MT
Step Code (0/1)
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...