VOL.2-979
MG-PRI/PRA
20.
SET
Δ
TCS_COMMON1
Δ
[
P1
]
This command is used to specify common data 1 for T1/E1. When not specify an attribute on the interactive
setting, the original setting keeps being used. To make this assignment effective, it is required to execute
the "SAVE" command and to restart before exiting the maintenance command.
Note:
Default of “Music No” is “0 = Fur Elise” when the program version is SW423 2B or earlier.
P1
-Specify a set value
0000-FFFF
= Set value (default value: 0201)
When
P1
is omitted
→
COMMAND 1
When
P1
is specified
→
COMMAND 2
<COMMAND 1>
1) Disable/Enable Remote Alarm Sending
0/1
=Enable(default)/Disable
2) Disable/Enable Signal All
0/1
=Disable(default)/Enable
3) Disable/Enable Idle Code Sending
0/1
=Disable(default)/Enable
4) Disable/Enable Dch Back-up
0/1
=Disable(default)/Enable
5) Disable/Enable Layer 1 Alarm Sending
0/1
=Enable(default)/Disable
6) Disable/Enable Haul Mode
0
=Short (default)
1
=Long
7) Disable/Enable EC NLP Control
0/1
=Disable/Enable (default)
8) Specify EC NLP Mode
0
=Background Noise (default)
1
=Fixed Level
9) Disable/Enable EC 2100Hz Detect
0/1
=Disable(default)/Enable
10) Select Music Source
0
=Internal (default)
1
=External
11) Specify Music No.
0
=Fur Elise
1
=Maiden’s prayer
5
=Minuet (default)
12) Specify clock mode
0
=Secondary (default)
1
=Primary
13) Disable/Enable Layer 1 Alarm LED display
0/1
=Enable/Disable (default)
A command is executed, and the result is displayed.
<COMMAND 2>
A command is executed, and the result is displayed.
MG-PRI > SET TCS_COMMON1
Remote Alarm Sending ( 0/1:0 ): 0
Signal All 1 ( 0/1:0 ): 0
Idle Code Sending ( 0/1:0 ): 0
Dch Back-up ( 0/1:0 ): 0
Layer 1 Alarm Sending( 0/1:0 ): 0
Haul Mode ( 0/1:0 ): 0
EC NLP Control ( 0/1:1 ): 1
EC NLP Mode ( 0/1:0 ): 0
EC 2100Hz bypass ( 0/1:0 ): 0
Music Int/Ext ( 0/1:0 ): 0
Music No. ( 0-12:5 ): 5
Clock Mode (0/1:0):0
Layer1 Alarm Display (0/1:1):1
set value is 0x0215
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
COMMAND 1
MG-PRI > SET TCS_COMMON1 0215
set value is 0x0215
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
COMMAND 2
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...