VOL.2-759
MG-BRI
11.7 Operation and Maintenance
This section explains the operation and maintenance procedure of MG-BRI. Data is assigned Terminal Software
installed in External Maintenance Terminal (PC).
11.7.1 How to Restore Config Data by Serial Connection (Local Download)
This config download/upload is performed one by one, connecting a PC to each MG-BRI with a RS-
232C and a LAN cable. Prepare the following:
- RS-232C cable is required.
- Serial terminal emulation program (such as HyperTerminal) is required
- LAN cable (crossover) is required for restoring config data.
- PCPro has to be installed in advance.
•
Backing Up Config Data By Serial Connection
STEP 1
Power off MG-BRI and disconnect it from the network.
STEP 2
Connect PC to MG-BRI by using RS-232C cable.
STEP 3
Power on MG-BRI.
STEP 4
Activate HyperTerminal and set the following:
Bit per second:9600bps
Data bits:8bit
Parity:None
Stop bit:1bit
Flow control:None
STEP 5
Select
[Transfer]
->
[Capture File...]
.
STEP 6
Send File screen is displayed. Specify a file name to be saved, and then click the Start button.
STEP 7
At the moment that boot programming is starting (While “
Starting MG-BRI boot pro-
gram
” is being displayed for approximately five seconds), press the ESC key.
STEP 8
After <Boot mode> Main menu is displayed, enter “1” (Configuration Data).
STEP 9
After <Configuration mode> Main menu is displayed, enter “2” (Custom).
STEP 10
After a prompt (
MG-BRI>
) is displayed, enter “show config” to display configuration data
of the MG-BRI.
STEP 11
Select
[Transfer]
->
[Capture Text]
->
[Stop]
to save the config file shown in screen.
POWER
B
D
B
D
ON
LINE
LINE 0
LINE 1
Tx/Rx
LINK
MG-2B
Serial Console
MG(BRI)
RS-232C cable
Configdata
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...