VOL.2-2200
SR-MGC
•
“SR–MGC No. Individual” radio button:
Click to specify the target SR–MGC number to copy office data.
SR–MGC Number:
Click to specify the SR–MGC number (0–255) to copy office data.
The clicked number will be displayed in “yellow.”
Re–click the number to cancel the office data copy and the display changes to “white.”
•
“All SR–MGC No.” radio button:
Click to execute office data copy to all the SR–MGCs in the network.
The number with SR–MGC implemented will be displayed in “yellow.”
The number without SR–MGC implemented will be displayed in “gray.”
When there is linkage to FCCS Cluster, the number will be displayed in “magenta” if SR–MGC is
implemented in the backup node. In this case, Office Data Copy is unavailable.
The meaning of the display colors are indicated below.
[11] Initialize SR–MGC (SR T and SR S)
After finishing office data copy, the Telephony Server (MGC) requests the SR-MGC to initialize. Wait for
the SR-MGC to be initialized, which takes about five minutes.
<About SR-MGC initialization>
If Office Data Copy is performed in the following status, initialization of SR–MGC is required.
- when office data file does not exist on the CF card of SR–MGC
- after the change of the office data requiring MGC initialization
To initialize SR–MGC, use either of the following methods.
(1) Initialize SR–MGC using the
CMNT
command’s “Initialize” tab (
CMNT
command only targets SR T):
<Initialize Tab>
•
“ALL” radio button:
Execute initialization to all the SR–MGCs in the network.
Colors
Meanings
Gray
SR–MGC number unimplemented
White
No request for Office Data Copy
Yellow
Office Data Copy request is in queue (request exists)
Blue
Office Data Copy is running
Green
Office Data Copy was successful
Red
Office Data Copy failed
Magenta (Pink)
SR–MGC number implemented in backup node
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...