VOL.2-589
MG-COT Card [SCA-6COTA/SCA-6COTC]
5.
Setting IP address and port number of DRS
Note:
The designated DRS setting cannot be applied when SP mode. Assign the Proprietary Protocol mode before
executing this DRS setting.
Note:
The value in [ ] shows the current setting. Press enter key to apply the current setting shown in [ ].
Note:
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
mand.
Note 1:
About IP address of DRS (Telephony Server), refer to “Registration Destination of IP Devices/Stations” in
INTRODUCTION of Installation Manual.
6.
Setting ToS of DRS session
MG-COT > SET DRSADDRESS
DRS Unit (1:Primary/2:Secondary/3:Tertiary/
4:Forth) : 1
DRS IP Address [0.0.0.0] : 150.10.1.100
DRS Port Number (1024-65535) [3456] : 3456
Line 2: Select “1” for the Telephony
Server in normal condition.
Line 3: Enter IP Address of DRS. (e.g.
150.10.1.100)
Line 4: Enter Port Number of DRS
(1024-65535, default = 3456).
DRS setting succeeded.
Line 5: Result is shown.
MG-COT > SET DRSTOS PRECEDENCE
PRECEDENCE (0-7) : 6
DELAY (0/1) : 0
THROUGHPUT (0/1) : 0
RELIABILITY (0/1) : 0
COST (0/1) : 0
Line 1: Enter sub command name
PRECEDENCE to set the
parameters such as Delay,
Throughput, Reliability, and
Cost. Specify the value to each
parameter.
Line 2: Precedence:0-7(low-
high)(default=6)
Line 3: Delay:0/1=Nomal(default)/Low
Delay ON
Line 4: Throughput:0/
1=Nomal(default)/High
Throughput ON
Line 5: Reliability:0/1=Nomal(default)/
High Reliability ON
Line 6: Cost:0/1=Nomal(default)/Cost
Precedence ON
DRS TOS setting succeeded.(0xC0)
Line 7: Result is shown.
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...