VOL.2-891
MG(BRI) [SCA-2BRIA/MG-2BRIA]
10. SET OWN_IPADDRESS
Assignment of IP Address, Subnet Mask, and Host Name of MG(BRI) itself.
Note:
Assign the IP Address first, then Subnet Mask.
Note:
Do not assign the following addresses (network address, broadcast address) to MG(BRI).
(example)
- IP address 192.168.1.0/Subnet mask 255.255.255.0 (192.168.1.0 is network address, improper)
- IP address 176.16.0.0/Subnet mask 255.255.0.0 (176.16.0.0 is network address, improper)
- IP address 192.168.1.255/Subnet mask 255.255.255.0 (192.168.1.255 is broadcast address, improper)
- IP address 176.16.255.255/Subnet mask 255.255.0.0 (176.16.255.255 is broadcast address, improper)
Note:
Execute the “SAVE” command before finishing the maintenance command to reflect change.
11. SET RTP_START_PORT_NO
Specify the first port number to be used for RTP.
Note:
Execute the “SAVE” command before finishing the maintenance command to reflect change.
Note:
Assign any even-numbered port number to the RTP start port. The specified data + 1 (the next odd-num-
bered port number) is automatically assigned as the RTCP port number.
Note:
24 ports are occupied following the RTP start port. More than 24 of consecutive vacant ports must be re-
served from the specified port number to the last 65535.
MG-BRI>set own_ipaddress
OWN IP address: 10.41.1.100
Assign the IP Address of MG(BRI).
(Default: 0.0.0.0)
Subnet mask: 255.255.255.0
Assign the Subnet Mask of MG(BRI).
(Default: 0.0.0.0)
Is there the Host Name? [Y/N]: y
Asked whether to use host name.
Y: Use host name
N: Not use host name
Host Name: mgbri.nec.com
Assign the MG(BRI)’s host name in full-
domain, up to 63-byte of characters, .
(period) and - (hyphen) is available.
(Default: blank)
Default configuration is ‘0.0.0.0/0.0.0.0/blank’,
if you will not change a configuration by using this command.
In order to make a setup reflect and keep, re-starting is
required after saving a configuration data by SAVE command.
MG-BRI>set rtp_start_port_no
Port Number (1024-65512): 1024
Port number (1024-65512)
(default: 1024)
Default configuration is ‘1024’,
if you will not change a configuration by using this command.
In order to make a setup reflect and keep, re-starting is
required after saving a configuration data by SAVE command.
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...