VOL.2-2139
SR-MGC(S)
STEP 8: Connect PCPro (PC) outside your LAN.
Connect a PC with PCPro installed to the SR-MGC(S) through the Ether1 connector on it, so
that you can assign office data to the SR-MGC(S).
Note:
If connecting them directly, use a LAN cable (crossover cable); if connecting via a HUB, use LAN cables
(straight-through cables).
STEP 9: Configure PCPro.
Set data to connect PCPro to the SR-MGC(S).
[PCPro Connection Account Setting]
On the Main Menu, click on System; click on Connection Account Setting; set the following.
Account Name
Connection Type: TCP/IP
TCP/IP Setting
IP Address: 172.16.253.0, a default IP address of an SR-MGC(S)
Port Number: 60000
[PC Setting]
A PC with PCPro needs to have an IP address, subnet mask, and default gateway address set
as follow. After you finish setting, restart the PC.
IP address: 172.16.253.253
Subnet mask: 255.255.0.0
Default gateway address: 172.16.253.0, a default IP address of an SR-MGC(S)
Now you are supposed to be able to login to the SR-MGC(S).
Perform the following to check the connectivity between the PC and SR-MGC(S).
[1]
Open a DOS window; enter
ping 172.16.253.0
; press the Enter key.
[2]
Make sure that you get replies from the SR-MGC(S) (172.16.253.0).
[3]
Turn on PCPro and login to the SR-MGC(S).
Now you can assign office data.
STEP 10: Set an IP address on the SR-MGC(S).
Set network data including an IP address and health check. For the procedure to set an IP ad-
dress of an SR-MGC(S), see the UNIVERGE SV8500 Data Programming Manual - Business.
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...