VOL.2-1750
MG-SIP16
37 SET
Δ
SIP_QOS
This command is used to specify the QoS of Session Initiation Protocol (SIP).
38 SET
Δ
SIP_REGISTER
The command is used to assign an IP address or a Fully Qualified Domain Name (FQDN) to the SIP reg-
istrar. This command is required for using a Proxy Server.
When
IP address
(=0) is selected
:
When
FQDN
(=1) is selected
:
Note 1:
Be sure not to enter a space after FQDN characters.
39 SET
Δ
SIP_ROUTE
This command is used to specify route information in the SIP side network. The registered number of the
route information is up to 10.
MG(SIP) > set sip_qos
See SET DRS_QOS command for more details.
MG(SIP) > set sip_register
SIP register type(0=IP address/1=FQDN):_
• Select the registrar type.
0: IP address
1: FQDN
MG(SIP) > set sip_register
SIP register type(0=IP address/1=FQDN):0
SIP register IP address: 192.168.100.100
SIP register port number(1024-65535): 5060
SIP register expires time(1-65535): 3600
• When IP address (=0) is selected.
• Assign the IP address of the SIP registrar (default: 0.0.0.0).
• Assign the port number of the SIP registrar (default: 5060)
• Assign the registrar alive time in seconds (default: 3600).
MG(SIP) > set sip_register
SIP register type(0=IP address/1=FQDN):1
Full Qualified Domain Name(MAX63): nec.com
SIP register port number(1024-65535): 5060
SIP register expires time(1-65535): 3600
• When FQDN (=1) is selected.
• Assign the FQDN (default:0, max 63 characters).
• Assign the port number of the SIP registrar (default: 5060)
• Assign the registrar alive time in seconds (default: 3600).
MG(SIP) > set sip_route
See SET IPX_ROUTE command for more details.
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...