VOL.2-2080
VS-32(Dual) [SCA-VS32VA/MG-VS32VA]
Sub command not found.
The entered sub command is not supported.
Enter supported sub command.
System data file (sysdata) corrupted. Initialize sys-
tem data with “INIT CONFIGDATA” command.
The system data file is corrupted.
Initialize the system data using the INIT CONFIG command.
Too many parameters.
Unnecessary parameter is entered.
Confirm if the entered parameter is required.
VLAN ID is already registered.
Specified VLAN ID is already used.
Enter new VLAN ID.
VLAN ID is not registered.
VLAN ID is not registered.
Register VLAN ID.
Illegal Format: Codec=0x000X
CODEC for Wave file must be PCM A-law(0x0006) or PCM
μ
-
law(0x0007).
Illegal Format: Channel=0x000X
The sound is not mono. Please change it to mono sound (0x0001).
Illegal Format: Rate=XXXX
The sampling period of music source must be 8kHz (8000).
Please change it to 8kHz.
Illegal Format: Byte Per Sec=XXXXXX
The sampling period of music source must be 8kHz and 8bits (8000).
Please change it to 8 bit and 8kHz.
Illegal Format: Byte Per Block=XXXXXX
The digitalization sampling type of music source must be mono (1).
Please change it to mono type.
Illegal Format: Bit Per Sample=XXXXXX
The digitalization sampling of music source must be 8 bits (8).
Please specify it within 8bits.
Error Messages (related to registration in Proprietary Protocol mode)
ERROR MESSAGE
STATE
SOLUTION
VS32 is ONLINE.
Normal operation.
-
Registration is Started Now!
VS32(Dual) is trying registration.
Wait for a while and then check the operating state later. When the
VS32(Dual) keeps this state continuously, there is a possibility that op-
eration error may occur. Try power OFF
→
ON.
DRS Message Send Error!
VS32(Dual) cannot send message to DRS. Possible cause is:
•
Default gateway of VS-32(Dual) is not assigned (0.0.0.0).
Execute SHOW IPADDRESS command to check the default gateway
setting. Reassign when 0.0.0.0 is set.
Error Messages (Continued)
ERROR MESSAGE
CAUSE
SOLUTION
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...