VOL.2-1644
MG-SIP96
Note:
If you select one port in the number of port setting, be careful not to use the same RTP port number
(set by “set sip_rtp_port_no” or “set ipx_rtp_port_no” command) when setting the non-default
SIP network RTP base port number.
(26) ip_version
Setting of SIP side IP Version
This command is used to specify the IP version for the SIP side network.
[Setting Example]
Note:
The conditions of this command are as follows.
• This command is available for SP-3987 MGSIP PROG-B Issue 3 or later.
• After changing the IP version with this command, you also need to change the IP addresses configured with
the following commands before executing the “reboot” command.
- “DNS IP address” configured with “set dnsaddress”
- “SIP server IP address” configured with “set sip_server”
- “SIP register IP address” configured with “set sip_register”
When you change IPv4 to IPv6, IP address for Ether2 port configured with “set ipaddress” is generated by
MG-SIP96 after receiving the RA message.
• When you change the IP version with this command, see also the information in
(27) ipx_route
Setting of the route information in the Telephony Server network
This command is used to specify route information in the Telephony Server side network. The registered
number of the route information is up to 10.
The following figure shows an example of display.
When Route type = 0 is selected:
MG(SIP)> set ip_version
Select the setting of SIP side IP
Version.
0=IPv4 (default)
1=IPv6
Input: 1
Assign the IP version for the SIP side network.
0: IPv4 (Default)
1: IPv6
MG(SIP)> set ipx_route
Select Route type(0:Exit/1:None/2:Static):0
0: Exit
1: None (Default)
2: Static
Select “0”.
MG(SIP)>
Exit the command without executing any-
thing.
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...