Solution
: This problem might occur if a curtain wall with non-system panels joins
to a roof and the curtain wall does not have a rectangular shape. It would also
panel is simple, create an appropriate
panel type derived from the system
occur if you create a non-rectangular wall profile and then change that wall to a
curtain wall with non-system panels.
panel family. If not, try making the panel
in the wall or roof rectangular, and then
using a panel family of the desired (non-
rectangular) shape. The wall will then
conform to the non-rectangular shape
of the panel.
Problem
: If you place a curtain grid on a sloped glazing, such that the curtain
grid division results in a complex piece of geometry that Revit Architecture cannot
produce, this error occurs.
Cannot divide curtain grid by grid line.
Solution
: There is no workaround. You have to cancel the action.
Problem
: A curtain wall contains an ellipse in one of its sides. This problem could
happen if the wall joins to a roof with an ellipse.
Currently, only straight walls with
straight or arc edges are supported for
non-rectangular curtain walls.
Solution
: Cancel the command; this type of curtain wall is not supported.
Copy and Paste
Details
Informational Message
Problem
: Revit Architecture is unable to paste the selected component in the
view.
Cannot paste selection in [name] view.
Solution
: If you tried to paste a wall in an elevation view or a section view, you
see this message. Try pasting in a plan, reflected ceiling plan, or 3D view. This
message would also appear if you try to paste a group of components that cannot
be pasted into a certain view: for example, a column group into an elevation
view.
Problem
: Revit Architecture requires a proper host for the copied element (for
example, a window needs a wall, a tag or dimension needs reference elements).
Elements were deleted. Use Edit Pasted
Elements to keep them.
Solution
: If you tried to paste an element into a location that does not contain
a proper host, you will see this message. Click Cancel to remove the warning. On
the Options Bar, click the Edit Pasted Elements button. In the Edit Pasted mode,
place the copied element onto its proper host. Click Finish Paste to complete the
paste process.
TIP
Paste Aligned and Copy commands do not provide the Edit Pasted Elements
button. If you get this message in Paste Aligned or Copy command, you can
cancel and perform the Paste from Clipboard command instead.
Also see
Editing Pasted Elements
on page 322.
Roofs
Details
Informational Message
Problem
: Typically, this problem occurs in a panel on a sloped glazing. A hori-
zontal and vertical curtain grid on a panel are not meeting exactly at a point,
Can't create Curtain Panel. A Panel or a
Mullion is probably too small.
creating a small triangular panel within the main panel; the triangular panel
cannot be accurately regenerated because it is too small. This error can result
1336 | Chapter 23 Print Troubleshooting, Diagnostic Tools, and Error Handling
Summary of Contents for 24000-000000-9860 - Revit Architecture - PC
Page 1: ...Revit Architecture 2009 User s Guide April 2008 240A1 050000 PM02A ...
Page 4: ......
Page 56: ...18 ...
Page 116: ...78 Chapter 3 Revit Essentials ...
Page 172: ...134 Chapter 4 ProjectViews ...
Page 178: ...Schedule with Grid Lines Schedule with Grid Lines and an Outline 140 Chapter 4 ProjectViews ...
Page 554: ...516 ...
Page 739: ...Curtain wall Curtain Grid Curtain Walls Curtain Grids and Mullions 701 ...
Page 1004: ...966 ...
Page 1136: ...1098 ...
Page 1226: ...1188 ...
Page 1250: ...1212 ...
Page 1276: ...1238 Chapter 20 Design Options ...
Page 1310: ...1272 ...
Page 1366: ...1328 ...
Page 1406: ...1368 ...