In a project view, select a lighting fixture, and click
(Element Properties).
2
In the Element Properties dialog, click Edit/New.
3
Click Duplicate to create a new type.
4
Enter a name for the type, and click OK.
5
In the Type Properties dialog, for Light Loss Factor, click in the Value column.
6
In the Light Loss Factor dialog, specify the desired value.
See
Light Loss Factor Parameters
on page 1123.
7
Click OK 3 times.
Dimming Lights
When you dim lights in a 3D view for rendering, the settings are saved as part of the view properties, and
the lights are dimmed for that view only. The dimmed light settings do not affect rendered images for any
other 3D views.
NOTE
To specify the color temperature shift for dimmed lights, change type properties for the lighting fixtures.
Modify the value of Dimming Lamp Color Temperature Shift. See
Changing a Lighting Fixture in a Building Model
on page 1129.
To dim lights
1
Open the 3D view to render.
2
Define render settings.
See
Defining Render Settings
on page 1159.
3
In the Rendering dialog, under Lighting, for Scheme, select a setting that includes artificial
lights.
4
Click Artificial Lights.
5
In the Artificial Lights dialog, in the Dimming column, enter dimming values for light groups
or individual lighting fixtures.
Enter a value between 0 and 1 to indicate the relative amount of dimming. A value of 1 means
that the light is completely on (not dimmed). A value of 0 means that the light is completely
dimmed (off).
NOTE
If a lighting fixture is a nested family that contains multiple light sources but is not shared,
you cannot dim individual light sources in the fixture. See
Sharing a Lighting Fixture Family
on page
1107.
6
Click OK.
7
To see the effects of dimming the lights, render the image.
See
Creating the Rendered Image
on page 1168.
Light Groups
You can create groups of artificial lights in a building model. For example, you may want to create groups
for functional areas of a building, such as exterior lights, kitchen lights, hallway lights, and so on. Light
groups can include one or more lighting fixtures of multiple types.
1134 | Chapter 17 Rendering
Summary of Contents for 24000-000000-9860 - Revit Architecture - PC
Page 1: ...Revit Architecture 2009 User s Guide April 2008 240A1 050000 PM02A ...
Page 4: ......
Page 56: ...18 ...
Page 116: ...78 Chapter 3 Revit Essentials ...
Page 172: ...134 Chapter 4 ProjectViews ...
Page 178: ...Schedule with Grid Lines Schedule with Grid Lines and an Outline 140 Chapter 4 ProjectViews ...
Page 554: ...516 ...
Page 739: ...Curtain wall Curtain Grid Curtain Walls Curtain Grids and Mullions 701 ...
Page 1004: ...966 ...
Page 1136: ...1098 ...
Page 1226: ...1188 ...
Page 1250: ...1212 ...
Page 1276: ...1238 Chapter 20 Design Options ...
Page 1310: ...1272 ...
Page 1366: ...1328 ...
Page 1406: ...1368 ...