*01
01
S0X4A00G10123625331FEAT30
*01
S0X4A11G24100031441FEAT20
21-40
21-40
Heating/Air Conditioning
Evaporator Temperature Sensor
Test
Heater Fan Switch Test
EVAPORATOR TEMPERATURE SENSOR
40
30
20
10
RESISTANCE
k
50
10
68
20
86°F
30°C
TEMPERATURE
32
0
Terminal
Position
OFF
1
2
3
4
1
2
3
4
5
6
HEATER FAN SWITCH
1. Dip the sensor in ice water, and measure the
resistance between its terminals.
2. Then pour warm water on the sensor, and check for
a change in resistance.
3. Compare the resistance readings with the
specifications shown in the graph; the resistance
should be within the specifications.
Check for continuity between the terminals in each
switch position according to the table.
Terminal side of male terminals
03/07/29 10:11:08 61S0X050_210_0041
Summary of Contents for 2004 Odyssey
Page 33: ......
Page 59: ......
Page 145: ......
Page 167: ......
Page 229: ......
Page 259: ......
Page 283: ......
Page 309: ......
Page 613: ...03 07 29 09 29 07 61S0X050_140_0003...
Page 1097: ......
Page 1119: ......
Page 1363: ......
Page 1527: ...Top View 20 162 Frame Frame Repair Chart...
Page 1528: ...20 163 cont d...
Page 1529: ...Side View 20 164 Frame Frame Repair Chart cont d...
Page 1530: ...20 165...
Page 1594: ...21 63...
Page 1606: ...21 75...
Page 1677: ......
Page 1692: ...22 13 Roof REAR CONTROLLER and SCREEN With rear entertainment system...
Page 1696: ...22 17 1 2 BATTERY GROUND CABLE 3 4 5 6 ENGINE GROUND CABLE STARTER CABLE...
Page 2025: ......
Page 2439: ......
Page 2459: ......