*04
*01
S0X4A00G24113614602FAAT10
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
21-22
21-22
Heating/Air Conditioning
Recirculation Control Motor Circuit
Troubleshooting (cont’d)
Blower Motor Circuit
Troubleshooting
HEATER CONTROL PANEL 22P CONNECTOR
GRN/RED
GRN/RED
GRN/WHT
GRN/WHT
RECIRCULATION CONTROL MOTOR 7P CONNECTOR
HEATER FAN SWITCH 7P CONNECTOR
BLU/YEL
BLU/BLK
BLU/RED
BLU
10. Turn the ignition switch off.
11. Check for continuity between the following
terminals of the heater control panel 22P connector
and the recirculation control motor 7P connector.
22P:
7P:
No. 1
No. 7
No. 11
No. 5
Check for loose wires or poor connections at
the heater control panel 22P connector and at
recirculation control motor 7P connector. If the
connections are good, substitute a known-good
heater control panel, and recheck. If the symptom/
indication goes away, replace the original heater
control panel.
Repair any open in the wire(s) between the
heater control panel and the recirculation control
motor.
12. Remove the recirculation control motor (see page
21-39).
13. Check the recirculation control linkage and doors
for smooth movement.
Replace the recirculation control motor.
Repair the recirculation control linkage or
doors.
1. Turn the ignition switch ON (II) and the heater fan
switch ON.
Go to step 2.
Go to step 16.
2. Turn the heater fan switch OFF.
3. Make sure the ignition switch is ON (II).
Go to step 4.
Go to step 9.
4. Turn the ignition switch OFF.
5. Disconnect the blower motor 2P connector.
6. Disconnect the blower resistor 5P connector.
7. Disconnect the heater fan switch 7P connector.
8. Check for continuity between the No. 3, 4, 5 and 6
terminals of the heater fan switch 7P connector and
body ground individually.
Repair any short to body ground in the
wire(s) between the blower motor, the blower
resistor and the heater fan switch.
Replace the heater fan switch.
Wire side of female terminals
Wire side of female terminals
Wire side of female terminals
Is ther e continuity?
Do the r ecir culation contr ol linkage and door s
move smoothly?
Does the blower r un?
Does the blower motor r un?
Is ther e continuity?
03/07/29 10:10:23 61S0X050_210_0023
Summary of Contents for 2004 Odyssey
Page 33: ......
Page 59: ......
Page 145: ......
Page 167: ......
Page 229: ......
Page 259: ......
Page 283: ......
Page 309: ......
Page 613: ...03 07 29 09 29 07 61S0X050_140_0003...
Page 1097: ......
Page 1119: ......
Page 1363: ......
Page 1527: ...Top View 20 162 Frame Frame Repair Chart...
Page 1528: ...20 163 cont d...
Page 1529: ...Side View 20 164 Frame Frame Repair Chart cont d...
Page 1530: ...20 165...
Page 1594: ...21 63...
Page 1606: ...21 75...
Page 1677: ......
Page 1692: ...22 13 Roof REAR CONTROLLER and SCREEN With rear entertainment system...
Page 1696: ...22 17 1 2 BATTERY GROUND CABLE 3 4 5 6 ENGINE GROUND CABLE STARTER CABLE...
Page 2025: ......
Page 2439: ......
Page 2459: ......