Symptom
Diagnostic procedure
Also check for
21-72
Climate Control
Symptom Troubleshooting Index
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
The blower motor does not run
immediately even through the
engine is fully warmed up.
NOTE: The temperature control
dial must be set between 60°F
(18°C) and 90°F (32°C).
ECT sensor circuit
troubleshooting (see page 21-
106)
Cleanliness and tightness of all
connectors
Recirculation control doors do not
change between Fresh and
Recirculate.
Recircuration control motor
circuit troubleshooting (see
page 21-107)
HVAC DTCs (see page 21-67)
Blown fuse No. 3 (7.5A) in the driver’s
under-dash fuse/relay box
Cleanliness and tightness of all
connectors
Blower, heater controls, and A/C
do not work.
Climate control power and
ground circuit troubleshooting
(see page 21-112)
HVAC DTCs (see page 21-67)
Blown fuse No. 54 (40A) in the under-
hood fuse/relay box, No. 3 (7.5A) in the
driver’s under-dash fuse/relay box, and
No. 13 (7.5A) in the passenger’s under-
dash fuse/relay box
Poor ground at G401
Cleanliness and tightness of all
connectors
The climate control panel display
does not work.
Climate control panel
troubleshooting (see page 21-
114)
HVAC DTCs (see page 21-67)
Cleanliness and tightness of all
connectors
The manual switch (With
navigation system) does not work.
Manual switch (With navigation
system) troubleshooting (see
page 21-116)
HVAC DTCs (see page 21-67)
Cleanliness and tightness of all
connectors
Both fans do not run at low speed
with the A/C on when the
refrigerant pressure is below
1,520 kPa (15.5 kgf/cm , 220 psi).
Radiator and condenser fan low
speed circuit troubleshooting
(see page 21-27)
HVAC DTCs (see page 21-67)
Blown fuse No. 58 (30A) in the under-
hood fuse/relay box, and No. 3 (7.5A) in
the driver’s under-dash fuse/relay box
Poor ground at G201
Cleanliness and tightness of all
connectors
Condenser fans does not run at
high speed when the engine
coolant temperature is above
210°F (99°C) or the refrigerant
pressure is above 1,520 kPa (15.5
kgf/cm , 220 psi) with the A/C on.
Condenser fan high speed
circuit troubleshooting (see
page 21-30)
HVAC DTCs (see page 21-67)
Blown fuse No. 3 (7.5A) in the driver’s
under-dash fuse/relay box
Poor ground at G201
Cleanliness and tightness of all
connectors
Both fans do not run at high speed
with the A/C on when the
refrigerant pressure is above
1,520 kPa (15.5 kgf/cm , 220 psi).
Radiator and condenser fan
high speed circuit
troubleshooting (see page 21-
31)
HVAC DTCs (see page 21-67)
Cleanliness and tightness of all
connectors
Compressor clutch does not
engage. (but both fans run with
the A/C on)
Compressor clutch circuit
troubleshooting (see page 21-
32)
HVAC DTCs (see page 21-67)
Blown fuse No. 59 (7.5A) in the under-
hood fuse/relay box, and No. 3 (7.5A) in
the driver’s under-dash fuse/relay box
Cleanliness and tightness of all
connectors
A/C system does not come on
(both fans and compressor do not
work); heater is OK
A/C pressure switch circuit
troubleshooting (see page 21-
110)
HVAC DTCs (see page 21-67)
Cleanliness and tightness of all
connectors
2
2
2
03/07/29 10:12:08 61S0X050_210_0073
Summary of Contents for 2004 Odyssey
Page 33: ......
Page 59: ......
Page 145: ......
Page 167: ......
Page 229: ......
Page 259: ......
Page 283: ......
Page 309: ......
Page 613: ...03 07 29 09 29 07 61S0X050_140_0003...
Page 1097: ......
Page 1119: ......
Page 1363: ......
Page 1527: ...Top View 20 162 Frame Frame Repair Chart...
Page 1528: ...20 163 cont d...
Page 1529: ...Side View 20 164 Frame Frame Repair Chart cont d...
Page 1530: ...20 165...
Page 1594: ...21 63...
Page 1606: ...21 75...
Page 1677: ......
Page 1692: ...22 13 Roof REAR CONTROLLER and SCREEN With rear entertainment system...
Page 1696: ...22 17 1 2 BATTERY GROUND CABLE 3 4 5 6 ENGINE GROUND CABLE STARTER CABLE...
Page 2025: ......
Page 2439: ......
Page 2459: ......