background image

 

 

 

 

       

Helpful Hints for Using KEITH

®

 

WALKING FLOOR

®

 Unloading Systems 

 

Below is a short list of operational procedures and helpful hints to ensure your 
KEITH

®

 

WALKING FLOOR

®

 system provides years of good service. 

 
1.  The hydraulic pump and PTO system requires hydraulic pressure of 3000 PSI 

with a minimum of 30 gallons of oil per minute for proper operation.  

2.  The PTO/Pump system requires a pressure relief valve set at 2800 PSI. 
3.   End Dump truck PTO systems set at a maximum 2200 PSI hydraulic pressure 

will not operate a 

WALKING FLOOR

 system properly and could cause serious 

damage to the system. 

4.  The 

WALKING FLOOR

 system requires a minimum 40 gallon oil reservoir to 

ensure oil does not overheat during unloading and result in heat damage. 

5.  Properly installed, smaller oil reservoirs with coolers can be used. 
6.  A trailer equipped with a standard KEITH 

WALKING FLOOR

 drive is capable of 

unloading approximately 32 tons of material.  

7.  A trailer equipped with a heavy-duty KEITH 

WALKING FLOOR

 drive is capable 

of unloading up to 52 tons. 

8.  A trailer equipped with a KEITH 

WALKING FLOOR

 drive is capable of unloading 

most materials in 4 minutes or less, if the PTO/Pump is set up properly. 

9.  Unloading speed is a function of oil flow.  With an oil flow of 30 GPM, the 

average unloading time is 6 to 7 minutes for a 45 ft/13.5 m trailer. 

10. All 

WALKING FLOOR 

systems are designed for two way operation- loading or 

unloading material.  A “Control Valve” controls the forward or reverse floor 
movement.  

11. A partially opened or closed on/off Ball Valve will create heat damage and result 

in slower unload speeds.  Open and close the on/off valve completely. 

12. Heat damage will void the warranty on hydraulic components. 
13. Always make sure back doors are open before engaging the 

WALKING FLOOR

 

system.   

14. Never walk on or stand in the way of the material while unloading. 
15. Make sure quick couplers are fully connected. 
16. Be sure the quick couplers are connected correctly (Pressure to Pressure-Return 

to Return). 
 

 
 
 

Reviews: