A
A.1
Parameter list
A-775
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0868
Baud rate selection, CAN bus
(–> 6.1)
Min
Standard
Max
Unit
Data type
Effective
0
0
255
–
Unsigned16
PO
... is used to set the baud rate for the CAN option module (Robox company).
0
1000 kbit/s
1
800 kbit/s
2
500 kbit/s
3
250 kbit/s
4
125 kbit/s
5
100 kbit/s
6
50 kbit/s
7
20 kbit/s
8
10 kbit/s
>8
Reserved
0870
Module type
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
The parameter displays the control module type and firmware.
P0870 = UVWX
U
= 0
Drive type is ”SIMODRIVE 611 universal”
= x
Reserved for another drive type (x = 1 to 15)
V
= 0
Firmware for speed control
= 1
Firmware for positioning
W
reserved
X
= 1
Module, 2-axis for resolvers
= 2
Module, 2-axis for encoders with sin/cos 1 Vpp
= 3
Module, 1-axis for resolvers
= 4
Module ”SIMODRIVE 611 universal E”, 2-axis for encoders with sin/cos 1 Vpp
= 5
Module HR, 2-axis for encoders with sin/cos 1 Vpp
= 7
Module HR, 2-axis for resolvers
= 8
Module HR, 1-axis for resolvers
= 9
Module HR ”SIMODRIVE 611 universal E”, 2-axis for encoders with
sin/cos 1 Vpp
Note: The module version is displayed in P0871.
0871
Module version
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
... displays the version of the particular module.
A Lists
01.99
! 611ue diff !
04.05