Parameterizing using the display and operator unit
3-94
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The parameters of a drive are displayed in a numerical sequence.
By simultaneously pressing the PLUS and MINUS keys in the parame-
ter and sub–parameter display, it is possible to jump to the same para-
meter of the other drive.
The parameters of drive A are designated with ”A ...” and the parame-
ters of drive B with ”b ...”.
Parameters of drive A
Parameters of drive B
+
–
+
–
P
P
P
P
Fig. 3-6
Parameter display for drive A and B
Hexadecimal numbers are displayed in the following form:
_ _ _ _ _ 0. to F.F.F.F.F.F.
While a parameter value is being displayed, the associated parameter
or sub–parameter number is cyclically displayed every 10 seconds for
one second. This function can be enabled/disabled using P1650 bit 15.
P1650.15
= 0
Cyclic display is active (standard)
= 1
Cyclic display is inactive
The parameters, which are effective after POWER ON, are designated
in the parameter display by a point after the drive letters.
Designating parameters which are
effective after POWER ON
Fig. 3-7
Designating parameters which are effective after POWER ON
Parameters for
drives A and B
Representation of
hexadecimal
values
Displaying
parameter
numbers
Designating
parameters which
are effective after
POWER ON