6
6.7
Analog outputs
6-549
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-56
Signal selection list for analog outputs, continued
Signal
Normaliza-
tion
(corre-
sponds
to LSB)
Units
Bit
width
Shift
fac-
tor
Displayed
in
Operating
mode
No.
Normaliza-
tion
(corre-
sponds
to LSB)
Units
Bit
width
Shift
fac-
tor
Displayed
in
pos
n–set
Designation
71
Pre–control speed
(SRM, ARM)
–
x
–
6
24
RPM
P1711
(SLM)
–
x
–
6
24
m/min
P1711
72
System deviation,
position controller input
x
x
P0030
27
48
MSR
MSR
2
–11
73
Actual position value
x
x
P0021
19
48
MSR
MSR
2
–11
74
Position setpoint
x
x
P0020
19
48
MSR
MSR
2
–11
75
Velocity setpoint IPO
x
4)
x
P0023
30
48
MSR/s
P1743
76
Following error
x
x
P0029
27
48
MSR
MSR
2
–11
77
Following error, dynamic
model
x
x
–
27
48
MSR
MSR
2
–11
78
External position reference
value
(from SW 3.5)
–
x
P0032
19
48
MSR
MSR
P0403/P0404
2
–11
79
External velocity setpoint
(from SW 3.5)
–
x
–
30
48
MSR
P1744
80
DSC system deviation
(from SW 4.1)
x
–
P0915
4
32
–
P1745
81
DSC pre–controlled speed,
motor
(from SW 4.1)
DSC pre–control velocity,
motor (from SW 4.1)
x
–
P0915
6
32
RPM
P1711
82
DSC system deviation from
PROFIBUS PPO
(from SW 7.1)
x
–
P0915
6
32
RPM
P1711
83
Equalization controller input
(from SW 7.1)
x
x
–
4
24
Nm
N
P1713
84
Equalization controller output
(from SW 7.1)
x
x
–
4
24
RPM
P1711
84
Torque setpoint – master axis
(from SW 7.1)
x
x
–
4
24
Nm
N
P1713
499
3)
PROFIBUS PKW task (re-
quest) identification (from SW
5.1)
x
x
P1786:1
8
16
–
–
500
3)
PROFIBUS PKW response
ID (from SW 5.1)
x
x
P1787:1
8
16
–
–
501
3)
PROFIBUS control word 1
(STW1) (from SW 5.1)
x
x
P1788:x
1)
8
16
–
–
502
3)
PROFIBUS status word 1
(ZSW1) (from SW 5.1)
x
x
P1789:x
2)
8
16
–
–
6 Description of the Functions
01.99
04.99