4
01.99
4.10 Linear motors (1FN1, 1FN3 motors)
4-169
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
4.10
Linear motors (1FN1, 1FN3 motors)
4.10.1
General information on commissioning linear motors
Before commissioning motors, the following questions must be answe-
red:
Are all of the prerequisites for commissioning checked and were the
points in the checklist for commissioning checked (refer to Chap-
ter 4.1)?
Is there a control board with sin/cos 1 Vpp (refer to Chapter 1.3)?
Reader’s note
Detailed information on linear motors, encoders and power connection,
configuring and mounting are provided in:
Reference:
/PJLM/ Configuration Manual
1FN1, 1FN3 Linear Motors
Manufacturers/Service Documentation
The following checks can be made:
1. linear motors
– Which linear motor is being used?
– Is the motor in the list (refer to Chapter A.3.4)?
Yes
Which?
1FN _ _ _ _ – _ _ _ _ _ – _ _ _ _
No
Is the data of the ”unlisted” linear motor available?
(refer under the index entry
”Unlisted motor – Parameters for SLM”)
– Is the motor already mounted and ready to be powered up?
– If a cooling circuit is being used, is it functional?
General
information on
commissioning
linear motors
Checks in the
no–current
state
4 Commissioning
08.01