6
6.2
Positioning mode (P0700 = 3, from SW 2.1)
6-386
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
When the monitoring function responds, the drive is shutdown and fault
134 is issued (positioning monitoring). A changeover is made into the
tracking mode.
Table 6-30
Parameters for the positioning monitoring function
No.
Name
Min.
Standard
Max.
Units
Effective
0320
Positioning monitoring time
0
1 000
100 000
ms
Immedi-
ately
This parameter defines the time when approaching the position, after which the following error
must be within positioning window (P0321).
Note:
The following applies when setting the positioning and standstill monitoring:
Positioning monitoring time (P0320)
Standstill monitoring time (P0325)
0321
Positioning window
0
40
20 000
MSR
Immedi-
ately
This parameter defines the positioning window within which the position actual value must be
located after the positioning monitoring time has expired (P0320).
0
Positioning monitoring is de–activated
1
Positioning monitoring is active with this value
Note:
The following applies when setting the positioning and standstill monitoring:
Positioning window (P0321)
Standstill window (P0326)
The following is valid if the specified positioning window is not reached:
–
The motion block has not been completed
–
It is not possible to traverse the axis any further
–
After the time in P0320 has expired, fault 134 is issued (positioning monitoring)
The size of the positioning window influences the block change time.
The lower that this tolerance is selected, then the longer positioning takes. It also takes that
much longer until the next traversing block can be executed.