2
2.1
Installing/removing control boards and modules
2-63
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
From delivery date 04.2002 onwards, there will be a new
”SIMODRIVE 611 universal” or ”SIMODRIVE 611 universal E”
control board with a higher encoder resolution (refer to Chapter 1.3 or
1.4). This new hardware simultaneously replaces the previous types
and is coupled to the new software
SW 5.1.
6SN1118–0N
00–0AA
6SN1118–1N
00–0AA
”SIMODRIVE 611 universal” control board
”old”
”new”
Replacing the memory module
Replacing the option module
6SN1118–0NH10–0AA0 ”SIMODRIVE 611 universal E” control board
X302
Replacing control boards
6SN1118–
N
01–0AA
6SN1118–
N
01–0AA
6SN1118–0NH11–0AA0
(refer to Chapter 2.1 ”Installing/removing
an option module”)
(refer to Chapter 2.1 ”Installing/removing
a memory module”)
Fig. 2-3
Replacing a defective control board by a new one
A control board is installed/removed as follows:
1. Ensure that the power module is in a no–voltage condition.
2. Release the screw connection and withdraw the ”old” control board
from the power module.
3. Remove the memory module from the defective ”old” and insert
this into the ”new” control board, refer to Point ”Installing/removing a
memory module”.
4. Insert the ”new” control board and connect–up the equipment bus.
5. Install the ”SimoCom U” start–up tool with version 5.1 (or higher)
or, when using an ”older” version, observe the following information:
Replacing
defective control
boards by new
ones
How is a
control board
replaced?
2 Installing and Connecting-Up
01.99
02.02