5
5.6
Net data (PKW and PZD area)
5-240
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 5-19
Status word AktSatz for positioning
ZSW
1
Akt
Satz
Pos
Zsw
ZSW
2
Angular incr. encoder handwheel evaluation, bit 0 (from SW 8.1)
Reserved
MDI active (from SW 7.1)
External block change (from SW 7.1)
Angular incremental encoder handwheel evaluation, bit 1 (from SW 8.1)
Reserved
Reserved
Angular incremental encoder handwheel active (from SW 8.1)
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reserved
Reserved
2
5
2
4
2
3
2
2
2
1
2
0
Status, block selection
(Traversing block 0 to 63)
Note:
As long as the block is not active, a –1 is displayed. The actual block number is displayed with the input
signal ”activate traversing task”.
From the perspective of SIMODRIVE 611 universal, status signals are output signals and are described
in Chapter 6.4.6.
Also refer in the index under ”Output signal, digital ...”).
Status word
AktSatz
5 Communications via PROFIBUS DP
08.99
06.04