6
6.6
Analog inputs
6-540
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
6.6.5
Application example master/slave
The master/slave functionality is implemented using the analog inputs/
outputs.
The master enters the torque setpoint for the slave via an analog out-
put (terminals 75.x/15 or 16.x/15). Refer to Chapter 6.7).
Note
Master/slave operation is only possible for motors with encoders!
Speed
setpoint
1 signal
M
set
mode
0 signal
n
set
mode
Master drive
Slave drive
M
3
∼
M
3
∼
Rigid or quasi–rigid
connection, which can
also be released in
operation.
75.x/15
16.x/15
56.x/14.x
24.x/20.x
56.x/14.x
24.x/20.x
I3.x
for a rigid coupling
––> M
set
mode
with the coupling
released
––> n
set
mode
Dependent on
the mechanical
coupling
Torque
setpoint:
Signal No. 36
Fig. 6-57 Example: Coupling 2 drives with master/slave with analog I/O
!
Warning
If, for a master/slave configuration, the rigid mechanical coupling is
released (the coupling is opened) then at the same time the slave drive
must be changed over to n
set
operation as otherwise the slave drive
would accelerate in an uncontrolled fashion to the maximum speed.
Application
example
master/slave
6 Description of the Functions
01.99
! not 611ue !
08.01