SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Encoder x position actual value 2 ––> Additional position actual value
Different values are entered in Gx_XIST2 depending on the function
(refer to Fig. 5-17).
Priorities for Gx_XIST2
The following priorities should be considered for values in
Gx_XIST2:
Gx_ZSW.14 = 1?
Gx_XIST2
=
Error code
(refer to Table 5-24)
Gx_XIST2
=
Requested value
Gx_XIST2
=
Absolute value
yes
no
yes
no
yes
no
yes
no
Gx_XIST2 = 0
Gx_ZSW.13 = 1
Gx_ZSW.4 = 1
or
.5 = 1
or
.6 = 1
or
.7 = 1
Gx_ZSW.15 = 1?
Parking encoder?
Encoder fault?
Value x present?
Transmit absolute
value cyclically?
Fig. 5-17 Priorities for functions and Gx_XIST2
Resolution:
Encoder pulses
2
n
n: Fine
resolution
Number of bits for the internal multiplication
The fine resolution is defined via P1043/P1045 or P1042/P1044 for
the ”requested value” or the ”absolute value” in Gx_XIST2.
P1043
Encoder 1, fine resolution, absolute track G1_XIST2
P1045
Encoder 2, fine resolution, absolute track G2_XIST2
P1042
Encoder 1, fine resolution G1_XIST1
P1044
Encoder 2 fine resolution G2_XIST1
Gx_XIST2
5 Communications via PROFIBUS DP