A
A.1
Parameter list
A-825
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1235:8
1st power limit
Min
Standard
Max
Unit
Data type
Effective
5.0
100.0
900.0
%
Floating Point
immed.
The parameter value refers to the motor output (SRM) and the rated motor output (ARM).
Note: refer to the index entry ”Limits”
1237
Maximum generative power
Min
Standard
Max
Unit
Data type
Effective
0.1
100.0
500.0
kW
Floating Point
immed.
... allows the regenerative power for the rectifier/regenerative feedback module to be limited. An
appropriately lower value must be entered here especially when using a non-controlled NE
module.
Note: refer to the index entry ”Limits”
1238
Current limit value (ARM)
Min
Standard
Max
Unit
Data type
Effective
0.0
150.0
400.0
%
Floating Point
immed. (ARM)
The parameter value refers to the rated motor current (P1103).
Note: refer to the index entry ”Limits”
1240:8
Torque setpoint offset (speed-contr.) (ARM SRM)
Force setpoint offset (speed-contr.) (SLM)
Min
Standard
Max
Unit
Data type
Effective
–50000.0
0.0
50000.0
N
Floating Point
immed. (SLM)
–50000.0
0.0
50000.0
Nm
Floating Point
immed. (SRM ARM)
This parameter value is added to the torque setpoint and force setpoint (SLM) if the closed-loop
speed control is active (pos operation and nset operation with speed setpoint input). The pa-
rameter has no effect if, in the nset mode, open-loop torque controlled operation was selected.
Note: refer under the index entry ”weight compensation”
1241:8
Normalization of torque setpoint (ARM SRM)
Normalization of force setpoint (SLM)
Min
Standard
Max
Unit
Data type
Effective
1.0
10.0
50000.0
N
Floating Point
immed. (SLM)
1.0
10.0
50000.0
Nm
Floating Point
immed. (SRM ARM)
... defines the normalization for the torque setpoint and force setpoint (SLM) for open-loop
torque controlled operation at the analog input terminals 56.x/14.x and/or terminals 24.x/20.x
and displays the reference value for P0619.
Note: refer to the index entry ”Open-loop torque controlled operation”
1242:8
Torque setpoint offset (torque-contr.) (ARM SRM)
Offset, force setpoint (torque-controlled) (SLM)
Min
Standard
Max
Unit
Data type
Effective
–50000.0
0.0
50000.0
N
Floating Point
immed. (SLM)
–50000.0
0.0
50000.0
Nm
Floating Point
immed. (SRM ARM)
The value is added to the torque setpoint or the force setpoint (SLM).
Note: refer to the index entry ”Open-loop torque controlled operation”
1243:8
Normalization, torque/power reduction. (ARM SRM)
Normalization, force/power reduction. (SLM)
Min
Standard
Max
Unit
Data type
Effective
0.0
100.0
100.0
%
Floating Point
immed.
Note: refer to the index entry ”Torque/power reduction”
A Lists
01.99
! 611ue diff !
04.05