A
A.1
Parameter list
A-811
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1082
Calculate third-party motor
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Integer16
immed.
... the ”Calculate unlisted motor” function is started. Parameters P1105 (only SRM), P1147,
P1241, P1401 are pre-assigned, the ”calculate controller data” function executed and the ap-
propriate unlisted motor code entered into P1102.
By entering the third-party motor code in P1102, at the next POWER ON, possibly changed
motor data will no longer be overwritten by the catalog motor data (previous motor code).
0 –> 1 Third-party motor is being calculated, function is active
0
Function in inactive
Procedure for third-party motor:
Are all of the equivalent circuit diagram data known?
–
if no: Calculate the equivalent circuit diagram data via P1081
–
if yes: Enter all of the equivalent circuit diagram data and set P1082 to 1
Note:
At the end of the calculation, the parameter is automatically reset to 0 or an error code is written
into it (refer to P1080).
1083
Function selection, motor data optimization (ARM)
Min
Standard
Max
Unit
Data type
Effective
1
1
4
–
Unsigned16
immed. (ARM)
... the function number for motor data optimization is entered.
1
Calculate leakage inductance and rotor resistance
2
Calculate no-load current and magnetizing reactance
3
Calculate field-weakening speed
4
Calculate moment of inertia
Perform motor data optimization:
Step 1
P1083 = 1 and start with P1084 = 1 (if it is not 0, evaluate error code)
Calculated and written parameters: P1136, P1137, P1138, P1139, P1140, P1141
Step 2
P1083 = 2 and start with P1084 = 1 (if it is not 0, evaluate error code)
Calculated and written parameters: P1136, P1141
Step 3
P1083 = 3 and start with P1084 = 1 (if it is not 0, evaluate error code)
Calculated and written parameters: P1142
Step 4
P1083 = 4 and start with P1084 = 1 (if it is not 0, evaluate error code)
Calculated and written parameters: P1117
Note:
For a detailed description, please refer to the index entry ”Motor data optimization”.
A Lists
01.99
! 611ue diff !
04.05