1
1.3
”SIMODRIVE 611 universal” control board
1-33
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Reader’s note
Please observe the information in the ”readme.txt” file on the CD
for ”SIMODRIVE 611 universal”.
Settings
All drive–related settings of the control board can be made as follows:
– using the parameterizing and start–up tool SimoCom U on an
external PG/PC (refer to Chapter 3.3)
– using the display and operator unit on the front panel
(refer to Chapter 3.2)
– using PROFIBUS–DP
(parameter area, PKW area, refer to Chapter 5.6.7)
Software and data
The firmware and the user data are saved on a memory module
which can be replaced.
Terminals and operator control elements
– 2 analog inputs, 2 analog outputs per drive
– 4 digital inputs, 4 digital outputs per drive
– 2 test sockets
– POWER–ON RESET pushbutton with LED
– Display and operator unit
Safe start inhibit
The start inhibit is addressed via terminal 663 and is signaled back
using a relay with positively–driven signaling contacts (AS1/AS2).
Using the start inhibit, the energy feed from the drive to the motor is
interrupted.
When the ”safe start inhibit” function is correctly used, the signaling
contacts AS1/AS2 must be included in the line contactor circuit or
the EMERGENCY OFF circuit.
Caution
When using the ”safe start inhibit” function, it must be ensured that the
velocity goes to zero.
The control board supports the ”Safe standstill” function.
Detailed information about the ”Safe Standstill” function is provided
in
Reference:
/PJU/, SIMODRIVE 611,
Configuration Manual, Drive Converters
1 Product Overview
01.99
! 611ue diff !
02.02