A
A.1
Parameter list
A-748
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0171
Max. distance up to the zero pulse
Min
Standard
Max
Unit
Data type
Effective
0
20000
200000000
MSR
Unsigned32
PrgE
... specifies the maximum distance that the axis can traverse from leaving the reference (hom-
ing) cam or from the start, in order to find the zero pulse.
Note: refer to the index entry ”Reference point approach”
0172
Distance up to the zero pulse
Min
Standard
Max
Unit
Data type
Effective
–
–
–
MSR
Unsigned32
RO
... the distance moved from leaving the reference cam or from the start up to reaching the zero
pulse is entered.
The parameter supports, at stars-up, reference cam adjustments.
Note: refer to the index entry ”Reference point approach” and ”Reference cam adjustment”
0173
Reference point approach without reference cams
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
PrgE
0
Reference cam available
1
No reference cam available
Note: refer to the index entry ”Reference point approach”
0174
Referencing mode, position measuring system
Min
Standard
Max
Unit
Data type
Effective
1
1
2
–
Unsigned16
immed.
1
Incremental measuring system available
2
Incremental measuring system with equivalent zero mark available
(e. g. BERO at input terminal I0.x)
Note: refer to the index entry ”Referencing/adjustment”
0175
Adjustment status – absolute position measuring system
Min
Standard
Max
Unit
Data type
Effective
0
0
4
–
Integer16
immed.
... displays the status when adjusting the absolute value encoder.
–1
Error occured when adjusting
0
Absolute value encoder is not adjusted (pre-setting at the first stars-up)
1
Absolute value encoder has not yet been adjusted (encoder adjustment has been initi-
ated)
2
Absolute encoder is adjusted (before SW 3.1)
3
Absolute value encoder IM is adjusted (from SW 3.1)
4
Absolute encoder DM is adjusted (from SW 3.3)
Note: refer to the index entry ”Adjusting the absolute value encoder”
A Lists
01.99
! 611ue diff !
04.05