5
5.6
Net data (PKW and PZD area)
5-221
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 5-6
Control word STW1 for positioning
External block change (from SW 3.1)
Opening the holding brake for test purposes (from SW 4.1)
Start referencing/cancel referencing
Control requested/no control requested
Jogging 2 ON/jogging 2 OFF
Jogging 1 ON/jogging 1 OFF
STW
1
Reserved
Request passive referencing (from SW 5.1)
1)
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset the fault memory
Activate traversing task (edge)
Operating condition/intermediate stop
Operating condition/reject traversing task
Enable inverter/pulse inhibit
Operating condition/OFF 3
Operating condition/OFF 2
ON/OFF 1
Note:
The control signals, from the perspective of ”SIMODRIVE 611 universal”, are input signals and are
described in Chapter 6.4.3.
Also refer in the index under ”Input signal, digital ...”.
The signals which have been identified in this way, must have at least a 1 signal in order to
be able to start a traversing block using the control signal ”activate traversing task (edge)”.
1) QStw.1 is OR’d.
Control word
STW1
(pos mode)
5 Communications via PROFIBUS DP
08.99
08.01