Commissioning via SimoCom U
The following prerequisites must be fulfilled in order to be able to com-
mission a drive using the ”SimoCom U” parameterizing and start–up
tool:
1. All of the prerequisites for commissioning, according to Chapter 4.1,
have been fulfilled, i.e. the system with ”SIMODRIVE 611 universal”
can be commissioned.
2. The checklist for commissioning according to Chapter 4.1 has been
checked.
3. The ”SimoCom U” tool is installed on the PC/PG, which is to be
used to commission the drive.
4. There is a connecting cable between the PG/PC and the control
board (e.g. RS232 connecting cable, refer to Chapter 2.5).
5. The PC/PG with ”SimoCom U” is connected to the control board
(X471).
Reader’s note
Cable diagrams for the connecting cable refer to Chapter 2.5
Installing ”SimoCom U”,
Introduction to ”SimoCom U” and
establishing online operation
refer to Chapter 3.3