SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1261
i2t limiting, rated current power section current
(–> 3.1)
Min
Standard
Max
Unit
Data type
Effective
25.0
100.0
100.0
%
Floating Point
immed. (ARM)
25.0
110.0
110.0
%
Floating Point
immed. (SRM SLM)
... for the i2t power section limiting, it defines the limiting characteristic referred to i-n.
Note:
i-n = P1111 (rated power section current) x P1099 (limiting factor, power section currents)
refer to the index entry ”i2t power section limiting”
1262
i2t time in limiting
(–> 3.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
s
Floating Point
RO
... for the i2t power section limit, this is used to display the time during which the power section
is being limited.
Note:
The parameter is reset for value overflow and for POWER ON.
refer to the index entry ”i2t power section limiting”
1263
i2t actual limiting factor
(–> 3.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
%
Floating Point
RO
... for the i2t power section limit, this is used to display the actual current limit referred to i-max.
Note:
i-max = P1108 (limiting power section current) x P1099 (limiting factor, power section currents)
refer to the index entry ”i2t power section limiting”
1264
i2t actual utilization factor
(–> 4.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
%
Floating Point
RO
... is used for the i2t power section limiting to display the actual utilization. The difference to 100
% specifies how much reserve is available. The current limit is reduced for a utilization of 100%.
Note:
refer to the index entry ”i2t power section limiting”
1400
Rated motor speed (ARM SRM)
Rated motor velocity (SLM)
Min
Standard
Max
Unit
Data type
Effective
0.0
1450.0
100000.0
rpm
Floating Point
PO
(ARM)
0.0
0.0
100000.0
m/min
Floating Point
PO
(SLM)
0.0
0.0
100000.0
rpm
Floating Point
PO
(SRM)
1401:8
Speed for max. useful motor speed (ARM SRM)
Velocity for max. useful motor velocity (SLM)
Min
Standard
Max
Unit
Data type
Effective
–100000.0
0.0
100000.0
m/min
Floating Point
immed. (SLM)
–100000.0
0.0
100000.0
rpm
Floating Point
immed. (SRM ARM)
The parameter specifies the maximum useful motor speed and the useful motor velocity in
closed-loop speed controlled operation, and represents the setpoint for P0618.
Note:
The maximum useful motor speed, set via P1401:8, is not exceeded, independent of whether
the setpoint is entered via terminal or PROFIBUS.
refer to the index entry ”speed-controlled operation”