6
6.6
Analog inputs
6-538
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following parameters are available to parameterize the M
red
mode
using terminal 24.x/20.x:
Table 6-54
Parameter for the M
red
mode
Parameters
No.
Description
Min.
Stan-
dard
Max.
Units
Effec-
tive
0611
Voltage at terminals 24.x/20.x
–
–
–
V(pk)
RO
0613
Inversion terminal 24.x/20.x
0
0
1
–
Imme-
diately
For the torque/power reduction, internally only positive setpoints are effective. For a negative
analog setpoint at terminal 24.x/20.x, an inversion function must be switched–in.
0614
Smoothing time, terminal 24.x/20.x (SRM,
SLM)
(ARM)
0.0
0.0
3.0
1 000.0
ms
Imme-
diately
0615
Drift/offset correction terminal 24.x/20.x
–9 999.9
0.0
9 999.9
mV(pk)
Imme-
diately
Note:
These parameters are described in Chapter 6.6.3.
0620
Normalization voltage, torque/power reduc-
tion (SRM, ARM)
Normalization voltage, force/power reduction
(SLM)
5.0
10.0
12.5
V(pk)
Imme-
diately
1243:8
Normalization, torque/power reduction
(SRM, ARM)
Normalization, force/power reduction (SLM)
0.0
100.0
100.0
%
Imme-
diately
P0620:
... defines up to which maximum voltage, a reduction can be made.
P1243:8
... defines up to which maximum torque or power a reduction can be made.
The data is a percentage with the following reference:
Reference for torque: P1230 (1st torque limit)
Reference for power: P1235 (1st power limit)
M
effective
/P
effective
[%]
M
max/
P
max
10 V
V
Red
[V]
Example:
P1244 = 1 (neg. characteristic)
P0620 = 5 V
P1243 = 50 %
––>
with an input voltage
of 0 V to 5 V, the
torque/power can be
reduced from
50 % to 0 %, referred to
P1230/P1235
Note:
The actual reduction is displayed
in P1717.
0 V
M
effective
/P
effective
[%]
M
max/
P
max
V
Red
[V]
P1243
P1243
P0620
P0620
10 V
0 V
P1244 = 1
P1244 = 2
Parameter
overview
6 Description of the Functions
01.99
! not 611ue !
10.99