A
A.1
Parameter list
A-845
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1705
Voltage setpoint (rms)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
V(RMS)
Floating Point
RO
Displays the phase-to-phase voltage.
1708
Torque-generating current Iq
Min
Standard
Max
Unit
Data type
Effective
–
–
–
%
Floating Point
RO
... displays the torque-generating current Iq RMS.
Note:
The display of the torque generating current actual value is smoothed using a PT1 filter
(P1250).
The smoothed current actual value is displayed as an absolute percentage, where 100 % corre-
sponds to the maximum power module current (e. g. for an 18/36 A power module ––> 100 % =
36 A RMS).
1709
Significance, voltage representation
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Floating Point
RO
Note: Internal Siemens
1710
Significance, current representation
Min
Standard
Max
Unit
Data type
Effective
–
–
–
µ
A(pk)
Floating Point
RO
Note: Internal Siemens
1711
Significance, speed representation (ARM SRM)
Significance, velocity representation (SLM)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
m/min
Floating Point
RO
(SLM)
–
–
–
rpm
Floating Point
RO
(SRM ARM)
Note: Internal Siemens
1712
Significance, rotor flux representation (ARM)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
µ
Vs
Floating Point
RO
(ARM)
Note: Internal Siemens
1713
Significance torque representation (ARM SRM)
Significance, force representation (SLM)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
µ
N
Floating Point
RO
(SLM)
–
–
–
µ
Nm
Floating Point
RO
(SRM ARM)
Note: Internal Siemens
1716
Torque setpoint (ARM SRM)
Force setpoint (SLM)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
N
Floating Point
RO
(SLM)
–
–
–
Nm
Floating Point
RO
(SRM ARM)
... displays the actual torque setpoint or force setpoint (SLM).
Note:
The torque/force setpoint display is smoothed using a PT1 filter (P1252).
A Lists
01.99
! 611ue diff !
04.05