6
6.2
Positioning mode (P0700 = 3, from SW 2.1)
6-420
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-38
Parameters used to program traversing blocks, continued
No.
Effective
Units
Max.
Standard
Min.
Name
The position actual value when detecting a signal edge at input signal ”external block
change” is written into P0026 (position actual value, external block change).
Blk
Pos.
Vel.
Command
Pos. mode
Block change enable
0
100
100
POSITIONING
ABSOLUTE
CONTINUE FLYING
1
200
50
POSITIONING
ABSOLUTE
CONTINUE EXTERNAL
2
300
100
POSITIONING
ABSOLUTE
END
100
v
t
Example:
Programming
3 traversing blocks
Block 1 with
CONTINUE
EXTERNAL
0
1 signal
0 signal
Input signal
”external block change”
Block 0
Block 1
Block 2
Block 1, if no signal edge is detected
P0110 = 0
P0110 = 1
Position actual value in
P0026
Note:
Refer under the index entry ”Input signal – external block change”.
0087:64
Xxxx
Spindle positioning (from SW 5.1)
For the ”Spindle positioning” function, the target position is programmed in P0081 or trans-
ferred via PROFIBUS–DP.
Note:
Refer under the index entry ”Spindle positioning”
6 Description of the Functions
01.99
! not 611ue !
02.02