A
A.1
Parameter list
A-813
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1102
Motor code number
Min
Standard
Max
Unit
Data type
Effective
0
0
65535
–
Unsigned16
PO
The motor code number describes the connected motor according to a table.
Note:
refer to the index entry ”Motor code”
1103
Rated motor current
Min
Standard
Max
Unit
Data type
Effective
0.0
0.0
500.0
A(rms)
Floating Point
PO
1104
Maximum motor current (SRM SLM)
Min
Standard
Max
Unit
Data type
Effective
0.0
0.04
500.0
A(rms)
Floating Point
PO
(SRM SLM)
1105
Reduction in maximum motor current (SRM SLM)
Min
Standard
Max
Unit
Data type
Effective
0
100
100
%
Integer16
immed. (SRM SLM)
... reduces the maximum motor current (P1104) to the specified percentage.
Note:
If the motor current is at its limit, the monitoring intervenes with P1605/1606.
1106
Power section code number
Min
Standard
Max
Unit
Data type
Effective
0
0
65535
–
Unsigned16
PO
The power section code number defines the power section used.
Power section without automatic identification:
The module code must be selected from a table, and at first start-up, entered into P1106 (refer
under index entry ”power section code”).
Power section with automatic identification:
At the first start-up, the power section code of the power section used is automatically entered
in P1106.
if the value in P1106 and the value of the detected power section in P1110 differ when the drive
runs-up, then an appropriate fault is output.
Power mod. Ord. No. [MLFB] Power module code
6SN112x–1Ax0x–0HAx
1
6SN112x–1Ax0x–0AAx
2
6SN112x–1Ax0x–0BAx
4
6SN112x–1Ax0x–0CAx
6
6SN112x–1Ax0x–0DAx
7
6SN112x–1Ax0x–0GAx
8 (only for PE spindle)
6SN112x–1Ax0x–0EAx
9
6SN112x–1Ax0x–0FAx
10
6SN112x–1Ax0x–0JAx
11 (only for PE spindle)
6SN112x–1Ax0x–0KAx
12
6SN112x–1Ax0x–0LAx
13 (only for PE spindle)
A Lists
01.99
! 611ue diff !
04.05